Contraindications + Precautions

Aneurysm Clips
Back Brace
Cardiac Bypass Surgery
Contact Lenses
Dental Work
Eye and Ear Surgeries
Eye Shadow
Facial Reconstruction
Groshong Catheter
Halo
Hearing Anames
Heart Valves
Hernia Mesh
Embedded Wires/Stimulators/Batteries
Implanted Electrodes, Shunts, Pumps, or Other Electrical Devices
Intrauterine Device (IUD)
Joint Replacement
Leg Brace or Prosthesis
Lens Implants
Limb Replacement
Medication Patches
Nitroglycerin Patch
Orbital Implants
Pacemaker
Penile Implants
Pins/Screws
Pregnancy/Breast-feeding
Previous Metal in the Eyes
Rings
Rods in the Back
Shrapnel
Tubal Ligation
Tubes in the Ears
Vasectomy
Vena Cava Umbrella
Wires in the Chest from Heart Surgery

Aneurysm Clips – Most experts agree that patients who have had surgery for a brain aneurysm should never have an MR study. The clips used for brain aneurysms (even modern clips) may react to the magnetic pull. Other aneurysm clips are safe to be scanned, just not the ones in the brain.

Back Brace – This must be taken off prior to the MR scan.

Cardiac Bypass Surgery – Sometimes cardiac pacing wires are left in place after heart bypass surgery. It is very important for us to know if these wires are present. Pacing wire presence can be determined by having a recent chest x-ray reviewed. When you pre-register let us know if you have had heart surgery, and you will be informed if a chest x-ray review is needed.

Contact Lenses – It is safe to wear contact lenses if you can lie comfortably with your eyes closed.

Dental Work – This may cause an artifact (i.e. loss of picture information), but is safe for scanning. However, if you have an unusual amount of dental hardware and we are doing a scan of the head, some of the pictures may be affected. Dentures may need to be taken out for certain studies and you will be provided with a cup to put them in. Caps, crowns, pins, permanent wires, etc. can be scanned without a problem.

Return to List

Eye and Ear Surgeries – If you have had any eye or ear surgery, please notify us during your screening. There are certain eye/ear surgeries in which a metal implant is used and may cause harm to the patient, although most are safe. We may need to get the operative report or talk to the surgeon’s office. In some cases, an x-ray can identify metal implants if there is a question about this.

Eye Shadow – Some eye makeup has a metallic base and may cause your eyelids to flutter. Therefore, if you are having a study done of your head, please remove all eye makeup before coming to the MRI centre.

Facial Reconstruction – Any facial reconstruction, especially near the eyes, needs to be followed up on by one of our staff. We may need to get an operative report or a skull x-ray to verify the location of any implants or wires.

Groshong Catheter – This is usually safe to scan, however some of them have a small metal clip which needs to be removed prior to the scan.

Halo – This is a type of neck immobilizer, which may or may not be MR compatible, so it is important to tell the scheduler if you are in a halo.

Return to List

Hearing Anames – These must be taken off during all scanning procedures.

Heart Valves – Some heart valves are safe to scan; but some are not. Sometimes cardiac pacing wires are left in place after heart bypass surgery. It is very important for us to know if these wires are present. Pacing wire presence can be determined by having a recent chest x-ray reviewed. When you pre-register let us know if you’ve had heart surgery, and you will be informed if a chest x-ray review is needed.

Hernia Mesh – This is safe and will not cause you any harm, even if it is metal.

Embedded Wires/Stimulators/Batteries -These are put in for muscle problems, among other things. They can never be scanned and could cause bodily harm.

Implanted Electrodes, Shunts, Pumps, or Other Electrical Devices – Some of these are safe and some are not. Please be sure to tell the scheduling secretary if you have one of these and we will confirm whether it is safe for you to have the scan.

Return to List

Intrauterine Device (IUD) – Currently there are no known contraindications for an IUD.

Joint Replacement – If you have a hip replacement, knee replacement, etc., this is usually safe to scan. If the joint replaced is the joint being scanned, we do need the operative report because the images may not be optimal if there is a metal implant. However, it will not harm you to be scanned.

Leg Brace or Prosthesis – These need to be taken off prior to the MR study.

Lens Implants – Orbital lens implants are not a problem.

Limb Replacement – If a patient has a removable prosthetic device, it will need to be removed during the scan since most of them have metal components. If it is permanent, it will not cause you harm, however we should still be made aware of it.

Return to List

Medication Patches – Medication patches, such as nitroglycerin, birth control, or nicotine patches must be removed prior to scanning because some of them have a small metal wire inside and could cause injury.

Nitroglycerin Patch – We can never scan a patient with a nitroglycerin patch. It must be removed prior to scanning because they have a small metal wire inside and could cause injury.

Orbital Implants – Lens implants from cataract surgery are safe. Artificial eyes may need to be taken out prior to your study if they are removable. Please inform the scheduler if you have an orbital implant when reviewing the screening questions.

Pacemaker – We can never scan a patient with a pacemaker. The magnetic field would severely impair the function of the pacemaker. If you have a cardiac pacemaker, we will need to cancel your MR study and you should follow up with your doctor to find an alternative diagnostic study.

Penile Implants – Some penile implants may have metal components and we will need to find out the manufacturer and serial number of the implant. This can most often be obtained from the operative report.

Return to List

Pins/Screws/Wires – These metals, if surgically implanted because of broken bones, are generally no problem. However, if the metal wire/pin, etc. is put in place for any other reason, these should be reviewed on an individual basis. Most of these are safe to scan; however, some of them may cause problems for you so it is important to notify the scheduler of any metal implants.

Pregnancy/Breast-feeding – We normally do not scan pregnant women. If you think you might be pregnant, you must have a negative pregnancy test done or wait until your menstrual period before we can perform the scan. If you are breast-feeding, an unenhanced routine MRI/MRA is not a problem. However, if your scan is enhanced, you should plan to bottle-feeding the baby for 48 hours after the scan until the contrast material has passed through your system. There are no known side effects; but breast-feeding is not recommended for 48 hours following enhancement.

Previous Metal in the Eyes – If you have ever had any metal chips or fragments in your eyes from welding, grinding, or any accidents of any sort, an eye x-ray must be taken prior to the study. Even if the metal fragment was taken out, or came out on its own, or if it occurred a long time ago, an x-ray is the only way to confirm that there are no fragments remaining. This is important because if there are any small fragments in the eye, it could potentially damage the eyes. We will arrange these orbital x-rays prior to your scan. If there is any question about whether there may be metal in your eye, the x-ray must be taken.

Return to List

Rings – Rings are okay to keep on if they are difficult to get off. They will not be affected by the magnetic field and will not cause the patient any harm during the scan. One exception might be if we are scanning a hand or wrist since metal near the area of the scan may cause artifact or interference in the imaging. Earrings will need to be taken out, as will nose rings, lip rings, tongue studs, and other body piercings, etc.

Rods in the Back – These may cause artifact; but will not cause you harm. Depending on how big the rods are and the area we are scanning, this may/may not affect the results of your study.

Shrapnel – Shrapnel may present a problem. It is important to review each individual case with our staff. Depending on the location of the shrapnel, you may or may not be able to be scanned.

Tubal Ligation – Clips are no problem.

Tubes in the Ears – Tubes in ears (for recurrent infections) are safe.

Vasectomy – Any related clips are no problem.

Vena Cava Umbrella – We need to review an operative report regarding this implant. Some of these are not MR compatible.

Wires in the Chest from Heart Surgery – Although sternal wires are no problem during an MRI scan, sometimes cardiac pacing wires are left in place after heart bypass surgery. It is very important for us to know if these wires are present because they can cause you injury if certain types of MRI scans are being done. Pacing wire presence can be determined by having a recent chest x-ray reviewed. When you pre-register, let us know if you’ve had heart surgery, and you will be informed if a chest x-ray review is needed.